Hi all, I'm currently using the XDMF reader to read HDF5 files and this works fine both in serial and parallel mode. The HDF5 files come from a CFD code and only contain the primary flow variables (as multi-block structured 3D arrays). I have written a filter that calculates secondary flow variables - this also works well. However, the filter currently needs the user to input scalar values such as the specific heat capacity in order to calculate the secondary variables. What I would like to do is to read these in automatically from the XDMF or HDF5 files. So my question is, is there any way of getting the XDMF reader to read in the scalars and store them somewhere in such a way that they are accessible from the filter? If not, I guess I will have to modify the XDMF reader itself or open the XMDF/HDF5 file directly in the filter.
Best wishes, Tobias Brandvik _______________________________________________ Powered by www.kitware.com Visit other Kitware open-source projects at http://www.kitware.com/opensource/opensource.html Please keep messages on-topic and check the ParaView Wiki at: http://paraview.org/Wiki/ParaView Follow this link to subscribe/unsubscribe: http://www.paraview.org/mailman/listinfo/paraview