On Thursday 03 September 2009 09:04:20 am [email protected] wrote: > I have a (transient) *.encas file with some additional velocity and scalar > files. The files are created from FLUENT 6.3 in conjunction with fluents > dynamic mesh model. > > If i open my *.encase file with paraview 3.6.1, i get the following error > message: > > ERROR: In ..\..\..\src\VTK\IO\vtkGenericEnSightReader.cxx, line 412 > vtkGenericEnSightReader (1B8ACC40): Unable to open file: C:\Dokumente und > Einstellungen\Chefkoch\Desktop\TEST's\paraview-files\/C:\fluent-files\Parav >iew\faser-init0100.geo > > Warning: In ..\..\..\src\VTK\IO\vtkGenericEnSightReader.cxx, line 413 > vtkGenericEnSightReader (1B8ACC40): Assuming binary file.
I just had the same thing happen to me. The ensight checker warned me of the fact that my paths were absolute. Setting a relative path in Fluent for the ensight file (i.e. only specify a filename, don't start with C:\ or /) fixed this warning and the error in ParaView. P.S. Any chance that the .encas extension Fluent uses for EnSight Gold files could be added to ParaView? Cheers, -- Bart _______________________________________________ Powered by www.kitware.com Visit other Kitware open-source projects at http://www.kitware.com/opensource/opensource.html Please keep messages on-topic and check the ParaView Wiki at: http://paraview.org/Wiki/ParaView Follow this link to subscribe/unsubscribe: http://www.paraview.org/mailman/listinfo/paraview