Just another data point:
  OS X 10.5.8 Intel.
  Qt 4.5.3 built for i386 and x86_64 (Cocoa)
  ParaView 3.6.2 Release source downloaded and built with i386 Arch.

Grayed out filter after loading a data set (.vti file in my case). I guess I too will try Qt 4.6.0 and see what happens.
_________________________________________________________
Mike Jackson                  [email protected]
BlueQuartz Software                    www.bluequartz.net
Principal Software Engineer                  Dayton, Ohio

On Jan 12, 2010, at 7:03 AM, Berk Geveci wrote:

We are going to use Qt 4.6 for the ParaView 3.8 release so I recommend
that everyone building cvs use that (despite the warning about it not
being officially supported). Please let us know if you can reproduce
this with Qt 4.6.

-berk

On Sat, Jan 9, 2010 at 8:09 AM, Eric E. Monson <[email protected]> wrote:
Hey Erik,

I recently ran into this problem, too. I was building CVS ParaView for both i386 and x86_64 using Qt 4.5.3 built for both of those architectures, too, and using Cocoa. The problem went away when I switched to Qt 4.6.0 built for only x86_64 (Cocoa) and built ParaView for that architecture, too. I didn't do a systematic series to see which of these changes (single x86_64 arch or Qt 4.6.0 or both) made the difference, but it works now and hopefully will work for you with PV 3.6.2.

Talk to you later,
-Eric

------------------------------------------------------
Eric E Monson
Duke Visualization Technology Group


On Jan 8, 2010, at 9:42 PM, [email protected] wrote:

Hello,

I am testing a build of Paraview 3.6.2 on Mac OS X 10.6 Cocoa. I am using Qt 4.5.3, and built for the x86_64 architecture. After much trial and error, I got a .app package built, with my own filters installed in the Plugins folder of the .app. That was pretty exciting.

The app runs, but after the first filter is chosen from the Filters menu, the Filters menu becomes grayed-out and filters are no longer accessible. The first filter always loads and does what it is supposed to do. This applies to any Filter, my own or one from the standard distribution.

Further, if I delete the items in the pipeline, and load a new source or from a new reader, the Filters menu continues to be grayed out. It basically lets me choose one filter per session.

Is this me being bone-headed, or has anyone else encountered something like this? If I must, I will revert to a build for Carbon and i386. Hopefully I've learned enough from the past five weeks of trial-and-error the downgrade wouldn't be too difficult.

Any thoughts?

Thanks,
Erik
_______________________________________________
Powered by www.kitware.com

Visit other Kitware open-source projects at 
http://www.kitware.com/opensource/opensource.html

Please keep messages on-topic and check the ParaView Wiki at: 
http://paraview.org/Wiki/ParaView

Follow this link to subscribe/unsubscribe:
http://www.paraview.org/mailman/listinfo/paraview

_______________________________________________
Powered by www.kitware.com

Visit other Kitware open-source projects at 
http://www.kitware.com/opensource/opensource.html

Please keep messages on-topic and check the ParaView Wiki at: 
http://paraview.org/Wiki/ParaView

Follow this link to subscribe/unsubscribe:
http://www.paraview.org/mailman/listinfo/paraview

_______________________________________________
Powered by www.kitware.com

Visit other Kitware open-source projects at 
http://www.kitware.com/opensource/opensource.html

Please keep messages on-topic and check the ParaView Wiki at: 
http://paraview.org/Wiki/ParaView

Follow this link to subscribe/unsubscribe:
http://www.paraview.org/mailman/listinfo/paraview

_______________________________________________
Powered by www.kitware.com

Visit other Kitware open-source projects at 
http://www.kitware.com/opensource/opensource.html

Please keep messages on-topic and check the ParaView Wiki at: 
http://paraview.org/Wiki/ParaView

Follow this link to subscribe/unsubscribe:
http://www.paraview.org/mailman/listinfo/paraview

Reply via email to