I've checked the Ensight Gold format and against the reader of paraview and come to notice there's an error in the reader.

The ordering of values in the Ensight Gold format for a simmetric tensor is:

 SXX, SYY, SZZ, SXY, SXZ, SYZ

 but paraview seems to be reading:

 SXX, SYY, SZZ, SXY, SYZ, SXZ

 which is not correct...


 cheers,