I've checked the Ensight Gold format and against the reader of paraview
and come to notice there's an error in the reader.
The ordering of values in the Ensight Gold format for a simmetric tensor
is:
SXX, SYY, SZZ, SXY, SXZ, SYZ
but paraview seems to be reading:
SXX, SYY, SZZ, SXY, SYZ, SXZ
which is not correct...
cheers,
Ricardo Reis
'Non Serviam'
PhD candidate @ Lasef
Computational Fluid Dynamics, High Performance Computing, Turbulence
http://www.lasef.ist.utl.pt
Cultural Instigator @ Rádio Zero
http://www.radiozero.pt
Keep them Flying! Ajude a/help Aero Fénix!
http://www.aeronauta.com/aero.fenix
http://www.flickr.com/photos/rreis/
< sent with alpine 2.00 >_______________________________________________
Powered by www.kitware.com
Visit other Kitware open-source projects at
http://www.kitware.com/opensource/opensource.html
Please keep messages on-topic and check the ParaView Wiki at:
http://paraview.org/Wiki/ParaView
Follow this link to subscribe/unsubscribe:
http://www.paraview.org/mailman/listinfo/paraview