Hi Matt, This issue has been fixed, however, the changes have not been merged yet with master.
They will be available soon if you can wait. Otherwise, if you would like to try it out, I will be happy to push my branch to gitorious for you to try it out. Best, George On Tue, Feb 22, 2011 at 3:04 PM, Utkarsh Ayachit <[email protected]> wrote: > ---------- Forwarded message ---------- > From: Matthew Turk <[email protected]> > Date: Tue, Feb 22, 2011 at 2:59 PM > Subject: [Paraview] Enzo data > To: [email protected] > > > Hi, > > I'm somewhat new to ParaView, and I'm trying to load up Enzo data with > 3.10.0-RC1. I am able to open the Enzo .hierarchy file, but upon > loading I am greeting with numerous errors (one for every .cpu file, > in fact) of the type: > > ERROR: In > /Users/partyd/Kitware/ParaView-3.10/source/Servers/Filters/vtkEnzoReader.cxx, > line 1965 > vtkEnzoReader (0x122c2e5a0): Failed to open particles file .\DD0252.cpu0062 > > which end up with the block structure existing, but no data being made > available. Looking in the .hierarchy file, under the entry for the > CPU 0062 file (for instance, but this is true for all of the files) I > see: > > -- > Grid = 63 > Task = 62 > GridRank = 3 > GridDimension = 70 70 70 > GridStartIndex = 3 3 3 > GridEndIndex = 66 66 66 > GridLeftEdge = 0.5 0 0 > GridRightEdge = 0.75 0.25 0.25 > Time = 630.69842031748 > SubgridsAreStatic = 0 > NumberOfBaryonFields = 12 > FieldType = 0 1 4 5 6 7 8 9 10 11 12 19 > BaryonFileName = DD0252.cpu0062 > CourantSafetyNumber = 0.500000 > PPMFlatteningParameter = 0 > PPMDiffusionParameter = 0 > PPMSteepeningParameter = 0 > NumberOfParticles = 285659 > ParticleFileName = DD0252.cpu0062 > GravityBoundaryType = 0 > Pointer: Grid[63]->NextGridThisLevel = 64 > -- > > The .hierarchy file is including references relative to the .hierarchy > file, and I can verify that these files are there. My guess is that > these are being translated to using the windows-style path delimiter > (as seen above in the error message), and a brief examination of > Servers/Filters/vtkEnzoReader.cxx suggests that this *may* be the > case, as on lines 66 and 67 the delimiter is set to be "\" with these > lines: > > #define ENZO_READER_SLASH_CHAR '\\' > #define ENZO_READER_SLASH_STRING "\\" > > I'm not entirely sure how the ParaView reader internals work, but I > was wondering if somebody could give me a hint about this? Am I > loading the file wrong? > > Thanks very much for any ideas! > > Best, > > Matt > _______________________________________________ > Powered by www.kitware.com > > Visit other Kitware open-source projects at > http://www.kitware.com/opensource/opensource.html > > Please keep messages on-topic and check the ParaView Wiki at: > http://paraview.org/Wiki/ParaView > > Follow this link to subscribe/unsubscribe: > http://www.paraview.org/mailman/listinfo/paraview > _______________________________________________ Powered by www.kitware.com Visit other Kitware open-source projects at http://www.kitware.com/opensource/opensource.html Please keep messages on-topic and check the ParaView Wiki at: http://paraview.org/Wiki/ParaView Follow this link to subscribe/unsubscribe: http://www.paraview.org/mailman/listinfo/paraview