This can happen when the extents requested by the pipeline are not satisfied by the filter. Compare with what the request information method script says you can provide, with what is requested of and actually provides by the request data script.
David E DeMarle Kitware, Inc. R&D Engineer 21 Corporate Drive Clifton Park, NY 12065-8662 Phone: 518-881-4909 On Mon, Jun 4, 2012 at 11:53 AM, Hal Canary <[email protected]> wrote: > Hello, > > I have the following macro which creates a ProgrammableSource in ParaView. > I'm wondering why the script seems to be called three separate times: > > script = """ > import time > print 'Script was called.', > print time.strftime('%H:%M:%S')+'.%03d'%(time.time()%1.0*1000) > self.GetImageDataOutput().SetDimensions(100,100,1) > # ... do something expensive here ... > """ > script_request_information = """ > from paraview import util > util.SetOutputWholeExtent(self, [0, 100, 0, 100, 0, 0]) > """ > ps = ProgrammableSource( > OutputDataSetType='vtkImageData', > Script=script, > ScriptRequestInformation=script_request_information) > GetDisplayProperties(ps).Visibility = 1 > Render() > > It prints out once when I turn on visibility and two more times when I > Render(). How can I keep the script from running more than once? > > Thanks! > > -- > Hal Canary > _______________________________________________ > Powered by www.kitware.com > > Visit other Kitware open-source projects at > http://www.kitware.com/opensource/opensource.html > > Please keep messages on-topic and check the ParaView Wiki at: > http://paraview.org/Wiki/ParaView > > Follow this link to subscribe/unsubscribe: > http://www.paraview.org/mailman/listinfo/paraview _______________________________________________ Powered by www.kitware.com Visit other Kitware open-source projects at http://www.kitware.com/opensource/opensource.html Please keep messages on-topic and check the ParaView Wiki at: http://paraview.org/Wiki/ParaView Follow this link to subscribe/unsubscribe: http://www.paraview.org/mailman/listinfo/paraview