Hello,
the code which I am using is instrumented with Catalyst. I am trying to process simulation data using ResampleToImage filter and then to store the result on a disk. In the Python pipeline I have something like: adaptor_input = coprocessor.CreateProducer(datadescription, 'input') resample = ResampleToImage(Input=adaptor_input) resample.UseInputBounds = True resample.SamplingDimensions = [256, 256, 256] writer = servermanager.writers.XMLPImageDataWriter(Input=resample) coprocessor.RegisterWriter(writer, filename='resample_%t.pvti', freq=10) When I check the results in ParaView, the grid is correct but the data array appended on it contains only zeros. When I skip the filter and dump directly the adaptor_input, the data array contains correct values. Could you, please, help me to resolve this issue? Thank you. Kind regards, Petr
_______________________________________________ Powered by www.kitware.com Visit other Kitware open-source projects at http://www.kitware.com/opensource/opensource.html Please keep messages on-topic and check the ParaView Wiki at: http://paraview.org/Wiki/ParaView Search the list archives at: http://markmail.org/search/?q=ParaView Follow this link to subscribe/unsubscribe: https://public.kitware.com/mailman/listinfo/paraview