El 30/07/2013 18:33, Margaria, Cyril (Coriant - DE/Munich) escribió:

Hi PCE WG,

3)Treat this as an errata to RFC5440 ““The BANDWIDTH *of OT 1 and OT 2* object body have a fixed length of 4 bytes.”, and define new OT for GMPLS

PCErs, all

Rather than "Errata" :) consider it a liberal interpretation, but I guess this approach is a nice trade-off. Maybe a solution could be to define Ctypes 3 and 4 which are like 1 and 2 but allowing TLVs (generically), then define a TLV to encode GMPLS traffic parameters. The BW objects can have a 32 bit IEEE floating point encoding of the nominal rate. Current implementations support 1 and 2 with fixed size. New Ctypes can be addressed with "unknown object ctype", hopefully without strictly checking the object length.

Just my view, of course
R.