Atte André Jensen wrote: > Roman Haefeli wrote: > >> if '0' is not part of your >> intended argument range, you can check in your abstraction, if the >> argument is '0' and assume, when it is '0', that it was not specified. > > Ok, thanks. > > What can I do then about audio rate inlets? As far as I understand they > supply continious streams thus overriding and creation arguments I might > supply. Is there something like [sel~] that'll only send the signal on > should it be different from 0?
this is more tricky. what you are really asking for is a way to detect whether an inlet is connected. i don't know of any way. control signals can be "0" too... of course you could do something like [inlet~] | +--+ | [==~] [default_signal~] | | | | [*~ ] | | [+~] | but that is most likely not what you want. there is also a [sigzero~] object in zexy which gives you information on whether the entire signal block is "0" (you could do this with [env~] too...) but basically i would suggest to not do something like that at all. mfga.dr IOhannes _______________________________________________ PD-list@iem.at mailing list UNSUBSCRIBE and account-management -> http://lists.puredata.info/listinfo/pd-list