Hi João If the first bang is triggered, wait some time and if within this time frame the second is triggered as well, then you know the direction. It's actually mostly about timing and to make sure to clear the state after a certain time, if not both bangs are triggered within the time frame.
Check the attached (ugly; done with touchpad) patch. Roman On Tue, 2010-08-17 at 13:45 +0100, João de Brito Rocha Reis Vidigal wrote: > Hi again. > Here goes another problem! > > Ok. So I'm working with Arduino firmata here... > To expose to problem in a simple way, I have 2 sensors that are detecting a > door crossing. > The 2 detectors give an order to the door crossing: coming in or going out. > Now I just don't know how I can translate that to bang 2 different [bang( > depending on if someone's comming in or going out! > > Can you help me with that!? > Thanks
#N canvas 424 192 632 528 10; #X obj 81 -7 bng 15 250 50 0 empty empty empty 17 7 0 10 -262144 -1 -1; #X obj 116 -7 bng 15 250 50 0 empty empty empty 17 7 0 10 -262144 -1 -1; #X obj 77 251 symbol; #X msg 217 181 symbol left; #X obj 200 249 symbol; #X msg 94 178 symbol right; #X msg 242 120 symbol empty; #X obj 149 294 select empty; #X obj 234 362 print; #X obj 233 321 t a b; #X msg 347 53 stop; #X obj 415 86 t b b; #X obj 243 92 delay 1000; #X connect 0 0 5 0; #X connect 0 0 2 0; #X connect 0 0 12 0; #X connect 1 0 3 0; #X connect 1 0 4 0; #X connect 1 0 12 0; #X connect 2 0 7 0; #X connect 3 0 2 1; #X connect 4 0 7 0; #X connect 5 0 4 1; #X connect 6 0 2 1; #X connect 6 0 4 1; #X connect 7 1 9 0; #X connect 9 0 8 0; #X connect 9 1 11 0; #X connect 10 0 12 0; #X connect 11 0 10 0; #X connect 11 1 6 0; #X connect 12 0 6 0;
_______________________________________________ [email protected] mailing list UNSUBSCRIBE and account-management -> http://lists.puredata.info/listinfo/pd-list