This popped up on the list earlier... the sample rate gets set _after_ patches are loaded from the command line if -nogui is set. It's on my long list of things to try to fix. In the meantime, as a workaround, if you can namage to delay Pd's loading of the patch, even by a fraction of a second, it should get the proper sample rate.
cheers Miller On Tue, Nov 06, 2012 at 08:33:22PM +0100, Pierre Massat wrote: > Dear List, > > While trying to use oggwrite~ on my RPi I noticed that it complained about > being unable to change the samplerate from 0 to 44100. > I turns out that Pd launched from the command line with the -nogui flag has > a samplerate of 0 ! > Adding the "-r 44100" flag doesn't change anything, nor does adding the > "-alsa" flag. > I wonder what causes this, whether it is a bug or not, and how Pd manages > to work fine anyway (the only real problem i've had this far was with > oggwrite~)... > > Any clue? > > Cheers, > > Pierre. > _______________________________________________ > [email protected] mailing list > UNSUBSCRIBE and account-management -> > http://lists.puredata.info/listinfo/pd-list _______________________________________________ [email protected] mailing list UNSUBSCRIBE and account-management -> http://lists.puredata.info/listinfo/pd-list