Adam Maas wrote:
> I'm having some trouble with my LX in Av mode. Whenever it meters a 
> shutter speed of 1/125 or below it will open the shutter for an 
> unusually long time (like 1/2 second or longer). It seems to work fine 
> with faster shutter speeds (1/250 and above, metered), and works fine 
> when not in Av mode (the slower eletronically controlled speeds work 
> just fine). Batteries swapped after this started occuring, so its not a 
> battery issue.
> 
> Am I in for a CLA, or is there something I've missed?
> 
> -Adam
> 

I had a similar problem with my LX in the past.  It was I asked Pentax 
repair in Vancouver to correct when I had then check out my LX.

The problem re-occurred after I got it back from Pentax repair.  I 
noticed a small protrusion in the bottom of the battery compartment that 
was shorting out the batteries.  I glued a small piece of plastic over 
the protrusion and corrected the problem.

-- 