Adam Maas wrote: > I'm having some trouble with my LX in Av mode. Whenever it meters a > shutter speed of 1/125 or below it will open the shutter for an > unusually long time (like 1/2 second or longer). It seems to work fine > with faster shutter speeds (1/250 and above, metered), and works fine > when not in Av mode (the slower eletronically controlled speeds work > just fine). Batteries swapped after this started occuring, so its not a > battery issue. > > Am I in for a CLA, or is there something I've missed? > > -Adam >
I had a similar problem with my LX in the past. It was I asked Pentax repair in Vancouver to correct when I had then check out my LX. The problem re-occurred after I got it back from Pentax repair. I noticed a small protrusion in the bottom of the battery compartment that was shorting out the batteries. I glued a small piece of plastic over the protrusion and corrected the problem. -- David S. Nature and wildlife photography http://www.sheppardphotos.com -- PDML Pentax-Discuss Mail List [email protected] http://pdml.net/mailman/listinfo/pdml_pdml.net