My K10D malfunctioned and required factory repair.  I'll document the  
problem here in case other people have a similar issue and will know  
what they might expect regarding turnaround, mitigation, and results.

When the built-in flash was raised, AF ceased functioning and the  
shutter would not release, even in MF with confirmation of focus.   
Using different lenses did not matter.  The flash did not appear to  
charge, as the indicator was showing not ready (bad cap, maybe).   
Burst flash AF assist did not function either.  Battery tested as  
okay.  No other problems were apparent, and the camera functioned  
properly in non-flash mode or with an external flash.  To the best of  
my knowledge, the malfunction is not impact/fluid-related.  The body  
has been in use since December 2006.  I'm not sure about the number  
of exposures so far, but I'd guess ~5000.

I paid for 2nd day shipping each way to Pentax (Colorado?) from  
Oregon on March 23rd; Pentax does not cover shipping.  Bob at the  
camera shop (Citizen's Photo of Portland; nice guys, good shop) said  
this is the first manufacturer's defect he has had on a K10D to  
date.  In his recent experience, he said Pentax has been requiring  
approximately 10 business days turnaround.  I'm glad I never got  
around to selling my DL.

Best regards,

Michael Chan



-- 
PDML Pentax-Discuss Mail List