Brendan wrote:
> 
> mine seem to, I just checked, that insert, those tabs
> need to be on
> top so the upper condensor sorta sits on it to stay
> level ( flat side
> up on top, flat side down on the lower one ), mine had
> a few nicks and
> scratches, it appears you have to be careful putting
> them both in so
> don't drop either in. I think you can put the upper
> one in with out
> scratching it, but minor nicks ( 1mm and smaller )
> don't show when you
> focus on the neg. The real problem I'm having is
> getting the filters
> cut to fit that damn little tray.

You can use the below the lens filter holder with the Ilford filters
that come in plastic frames. They fit perfectly. I have to do this
because I replaced the condensers with a cold light, but the Ilford set
is very convenient.

> 
> --- Delano Mireles <[EMAIL PROTECTED]> wrote:
> > Thanks, guys.  I appreciate the response.  Can you
> > confirm whether the
> > condensers are supposed to touch or not?
> >
> > Thanks again!
> >
> > Delano
> >
> > on 4/9/02 11:29 PM, Brendan at [EMAIL PROTECTED]
> > wrote:
> >
> > > To add to this put one condensor in, flat side
> > down,
> > > then put the
> > > aluminum insert ( not the suplementary lens ) in,
> > then
> > > the other
> > > condesor fits in flat side facing up ( so the 2
> > now
> > > face each others
> > > curved ). I'm not sure how the suplementary one
> > goes
> > > in, I just put it
> > > in flat side down curved side up and it seems to
> > work.
> > >
> > > --- Paul Stenquist <[EMAIL PROTECTED]>
> > wrote:
> > >> The curved parts of the two condensers should
> > face
> > >> each other. The
> > >> supplementary glass rests on top of the upper
> > >> condenser with the curved
> > >> part facing up. Hope this helps.
> > >> Paul
> > >>
> > >> Delano Mireles wrote:
> > >>>
> > >>> Hi all,
> > >>>
> > >>> I'm hoping I can get an answer tonight as I'd
> > like
> > >> to take my "new to me"
> > >>> B-22 for a spin.
> > >>>
> > >>> I need to know how the actual condensers are
> > >> supposed to be installed in the
> > >>> "head".  I have two condensers and what I
> > believe
> > >> is the supplementary glass
> > >>> along with an aluminum 'insert'.  The
> > >> supplementary glass is surrounded by
> > >>> another aluminum ring.
> > >>>
> > >>> Anyone out there that can help me out?  Paul?
> > >>>
> > >>> Thanks!
> > >>>
> > >>> Delano
> > >>> -
> > >>> This message is from the Pentax-Discuss Mail
> > List.
> > >>  To unsubscribe,
> > >>> go to http://www.pdml.net and follow the
> > >> directions. Don't forget to
> > >>> visit the Pentax Users' Gallery at
> > >> http://pug.komkon.org .
> > >> -
> > >> This message is from the Pentax-Discuss Mail
> > List.
> > >> To unsubscribe,
> > >> go to http://www.pdml.net and follow the
> > directions.
> > >> Don't forget to
> > >> visit the Pentax Users' Gallery at
> > >> http://pug.komkon.org .
> > >>
> > >
> > >
> > >
> >
> ______________________________________________________________________
> > > Music, Movies, Sports, Games!
> > http://entertainment.yahoo.ca
> > > -
> > > This message is from the Pentax-Discuss Mail List.
> >  To unsubscribe,
> > > go to http://www.pdml.net and follow the
> > directions. Don't forget to
> > > visit the Pentax Users' Gallery at
> > http://pug.komkon.org .
> > -
> > This message is from the Pentax-Discuss Mail List.
> > To unsubscribe,
> > go to http://www.pdml.net and follow the directions.
> > Don't forget to
> > visit the Pentax Users' Gallery at
> > http://pug.komkon.org .
> >
> 
> ______________________________________________________________________
> Music, Movies, Sports, Games! http://entertainment.yahoo.ca
> -
> This message is from the Pentax-Discuss Mail List.  To unsubscribe,
> go to http://www.pdml.net and follow the directions. Don't forget to
> visit the Pentax Users' Gallery at http://pug.komkon.org .
-
This message is from the Pentax-Discuss Mail List.  To unsubscribe,
go to http://www.pdml.net and follow the directions. Don't forget to
visit the Pentax Users' Gallery at http://pug.komkon.org .

Reply via email to