----- Original Message -----
From: Alan Abbott
Subject: Film not fully fixed- help

You are a bit vague about whether you failed to use enough
solution to cover the film, or if the solution was not robust
enough to do the job. Either way, just refix the film in fresh
fixer, and rewash it.
You could just refix it in a tray of fixer.

William Robb

This message is from the Pentax-Discuss Mail List.  To
unsubscribe,
go to http://www.pdml.net and follow the directions. Don't
forget to
visit the Pentax Users' Gallery at http://pug.komkon.org .






> Hi All,
>        I have just developed two Delta 400 films
> (Ilfosol,Ilfostop,Hypam)
> Unfortunately, I do not appear to have put enough solution in
to 'fix'
> properly.
> The symptoms are that the edge of the film (sprocket holes) in
places is
> still opaque (very few exposures)
> I have put the film back in a tray with fixer in (covered). To
try and
> correct it.
> What is the recommendations from the list as to what to do if
I screw up
> again this way?
> It would be very diff to put the film whilst wet back on the
spirals.
> Should I wait until dry or do what I am doing?
> I usually only do one film at once and just took the volumes
off the
> bottom of the tank for two films.
> I obviously got it wrong with the fixer!
> Alan
>
> 'Those who do not learn from Dilbert are doomed to repeat it'
>
>
>

Reply via email to