i guess no one wanted to comment on this ? i'd love to get it useful

promise i won't resend  :)

ds

Dennis Saputelli wrote:
in 99SE
anyone know how to get the DRC in PCB for unconnected pads to work?
(on the 'Other' tab)

first observation
it says it detects 'pads w/ no tracks' but it seems that if you load a netlist using 'include single pin nets' that those pads will not be flagged due to the presence of a net label (i guess), but that's ok by me


so given that if i load a netlist with 'include single pin nets' unchecked and then
if i make a pad class with all the pads i know are ok to be N.C. then add a rule for that class in addition to 'whole board' then
all the unconnected pads in the class are grouped into one section of the DRC report and all the rest are in another section of the DRC report, but
ALL of the given pads from both rules light up DRC green, which makes it almost useless to me


i want to just light up pads that i have not specified as ok to be N.C.

TIA

Dennis Saputelli

_______________________________________________________________________
Integrated Controls, Inc.           Tel: 415-647-0480  EXT 107
2851 21st Street                    Fax: 415-647-3003
San Francisco, CA 94110             www.integratedcontrolsinc.com


____________________________________________________________
You are subscribed to the PEDA discussion forum

To Post messages:
mailto:[email protected]

Unsubscribe and Other Options:
http://techservinc.com/mailman/listinfo/peda_techservinc.com

Browse or Search Old Archives (2001-2004):
http://www.mail-archive.com/[email protected]

Browse or Search Current Archives (2004-Current):
http://www.mail-archive.com/[email protected]



Reply via email to