Leo Potjewijd wrote:

At 16-6-2005 09:56, [EMAIL PROTECTED] wrote:

I have 99SE and sp6 and have had problems with a design containing parts
over 14 characters and spaces, BUT, I couldn't tie it down to these parts
being the cause of my problems, maybe it's a case of "if it ain't broke,
don't fix it".


I think this is the best advice.....
The problem is sort of intermittant: yesterday the synchroniser worked once every session (the first time), today it is a bit of pot luck: sometimes it works straight away, sometimes I need to say 'Ignore' quite a few times...... Simply deleting the .cfg and .raf files seems to help a bit, too.

My experience has been that once the synchronizer has messed up, it is best to NEVER use the synchronizer again on that project. You create a netlist and load the netlist. The only downside to this procedure, other than a couple of extra clicks, is that it may wipe the net assignment of split planes. Generally, that is not too hard to rebuild. If you forget and use the synchronizer again, it will often rename a WHOLE bunch
of PCB components to the wrong component designator, or something nasty like
that.

Jon