Leo Potjewijd wrote:
At 16-6-2005 09:56, [EMAIL PROTECTED] wrote:
I have 99SE and sp6 and have had problems with a design containing parts
over 14 characters and spaces, BUT, I couldn't tie it down to these
parts
being the cause of my problems, maybe it's a case of "if it ain't broke,
don't fix it".
I think this is the best advice.....
The problem is sort of intermittant: yesterday the synchroniser worked
once every session (the first time), today it is a bit of pot luck:
sometimes it works straight away, sometimes I need to say 'Ignore'
quite a few times...... Simply deleting the .cfg and .raf files seems
to help a bit, too.
My experience has been that once the synchronizer has messed up, it is
best to NEVER
use the synchronizer again on that project. You create a netlist and
load the netlist.
The only downside to this procedure, other than a couple of extra
clicks, is that it
may wipe the net assignment of split planes. Generally, that is not too
hard to
rebuild. If you forget and use the synchronizer again, it will often
rename a WHOLE bunch
of PCB components to the wrong component designator, or something nasty like
that.
Jon