Laurie,
        I have never seen that problem with any library parts I have created. I 
would suggest that you look at the following. Where are your parts located with 
respect to 0,0 in the library? Do you have some small line, text or other item 
way off away from the part? The designators will locate themselves relative to 
the extents of your footprint.

Sincerely,
Brad Velander
Senior PCB Designer
Northern Airborne Technology
#14 - 1925 Kirschner Road,
Kelowna, BC, V1Y 4N7.
tel (250) 763-2329 ext. 225
fax (250) 762-3374



-----Original Message-----
From: Laurie Biddulph [mailto:[EMAIL PROTECTED]
Sent: Saturday, October 22, 2005 2:36 PM
To: [email protected]
Subject: [PEDA] Protel 99SE Footprints


I have created a number of component footprints for my pcb designs (Protel 
99SE). When placing these components the Designator and Part Type fields are 
always a long way off from the component unlike the footprints that were 
supplied with Protel. What do I need to do to the footprint to force these 
fields to start initially next to the footprint?

I know that, once applied, I can reposition using the `position field' (which 
by the way already defaults to Centre-Above and Centre-Below) but this has to 
be done with EVERY homemade footprint I have created.

Best Regards

(Mr) Laurie Biddulph
Mobile: 0404 846 943

Elby Designs
ABN: 70 022 727 605
http://www.elby-designs.com
 


____________________________________________________________
You are subscribed to the PEDA discussion forum

To Post messages:
mailto:[email protected]

Unsubscribe and Other Options:
http://techservinc.com/mailman/listinfo/peda_techservinc.com

Browse or Search Old Archives (2001-2004):
http://www.mail-archive.com/[email protected]

Browse or Search Current Archives (2004-Current):
http://www.mail-archive.com/[email protected]

Reply via email to