We need static linking in order to link an existing static IO library, but we did not know the PETSc static build configure option.
On Thu, Feb 20, 2020 at 2:30 PM Satish Balay <[email protected]> wrote: > BTW: What do you mean by 'Cray static library environment variable'? Is it > CRAYPE_LINK_TYPE? What is set to? What problems are you having? > > One can get shared library build of PETSc working with: > > export CRAYPE_LINK_TYPE=dynamic > > Satish > > On Thu, 20 Feb 2020, Satish Balay via petsc-users wrote: > > > You can build PETSc statically with configure option: > > > > --with-shared-libraries=0 > > > > Satish > > > > On Thu, 20 Feb 2020, Mark Adams wrote: > > > > > We are having problems linking with at Cray static library environment > > > variable, that is required to link Adios, and IO package. How does one > > > build with static PETSc libs? > > > Thanks, > > > Mark > > > > > > >