ASAP
I've got problem using PFC. I've tell you from the start. I use PB 6.5 for front end
and Sybase Adaptive Server v11.9.2 for the back end.
I use dataobject u_dw and I've activate the filter service for that datawindow.
And I ran the program, the program ran succesfully, but if I click the 'Value'
Tabpage at Build filter with, an error was occur.
That error was :
The database error has occured
Select error: The 'CREATE TABLE' is not allowed within a multi-statement
transaction in the 'tempdb' database
How can I solve this problem ?
--------------------- "The greatest good we can do for others is not to share our
riches but to reveal theirs" ---------------------
Rendy Theixar
PT. Surabaya Agung Industri Pulp & Paper Tbk
Email : [EMAIL PROTECTED]
URL : http://www.suryakertas.com
> [EMAIL PROTECTED] HOSTED BY IIGG, INC. FOR HELP WITH LIST SERVE COMMANDS, ADDRESS
> A MESSAGE TO [EMAIL PROTECTED] WITH THE FOLLOWING MESSAGE: help pfcsig
> SEND ALL OTHER INQUIRES TO [EMAIL PROTECTED]