On Wed, Mar 16, 2016 at 1:18 PM, Ashesh Vashi <ashesh.va...@enterprisedb.com > wrote:
> On Wed, Mar 16, 2016 at 6:32 PM, Dave Page <dp...@pgadmin.org> wrote: > >> Hi >> >> On Mon, Mar 14, 2016 at 12:21 PM, Murtuza Zabuawala >> <murtuza.zabuaw...@enterprisedb.com> wrote: >> > Hi Dave, >> > >> > Thank you for reviewing my patch. >> > >> > I have made changes according to your feedback. >> > >> > Please review updated patch. >> >> OK, I think it's in pretty good shape now. Here's what I hope are the >> last of the review comments, mostly minor things :-) >> >> - I'm allowed to edit ENUM label names, but PostgreSQL doesn't support >> that. >> >> - Security label fields resize in Edit mode. See recent changes by >> Arun to fix that elsewhere. >> >> - When editing a type, I cannot select a Grantee on the Privileges tab. >> > Is the grantor same as the current user? > > If yes - then it is a bug, otherwise it is by design. > Because - you can not change privileges of a grantee, when it was given by > some other grantor. > This is when adding new privileges - which basically doesn't work as the form won't validate because there is no grantee selected. > > But - if you delete the privileges for its grantor, it will remove > privileges for the privileges given by it too. (which is though, we have > not yet take care, and we will do it in later.) > > -- > > Thanks & Regards, > > Ashesh Vashi > EnterpriseDB INDIA: Enterprise PostgreSQL Company > <http://www.enterprisedb.com/> > > > *http://www.linkedin.com/in/asheshvashi* > <http://www.linkedin.com/in/asheshvashi> > >> >> - When adding a composite type, I cannot type/select directly in the >> grid, I have to expand the row. >> >> - If I click ADD to add a new member to a composite type whilst the >> previous row is expanded, the new row is added, but the expanded panel >> remains linked to the first row. >> >> - If I then click on the Edit button on the new row, I see two >> expanded panels, neither of which is attached to their row (and >> they're in the wrong order). I would only expect to see one panel at a >> time. >> >> - When creating an External type, the Input, Output, Send, Receive and >> Analyze function lists are all blank. Is this expected? I would have >> thought there would be system functions listed as there are for Typmod >> in/out. >> >> - Labels for Yes/No fields should typically end in a '?', e.g. >> "Variable?", "Preferred?" >> >> - s/Prefered/Preferred >> >> - Why does "Range" type have a frame around it? >> >> - If a field is there to select/display a function, it should have >> "function" at the end of its label, e.g. "Canonical function" >> >> - As above, but with type. E.g. "Element type" >> >> - Some of the combo boxes have hint text of "Select from the list", >> whilst others don't. This should be consistent. >> >> - The colouring of "No" on the switches should be blue (see "System >> Schema?") >> >> - s/Subtype/Sub-type/ >> >> - s/SubType diff/Sub-type diff function/ >> >> - Please remove the pre-9.1 support. >> >> - In def create(self, gid, sid, did, scid), ensure error messages are >> properly pluralised, e.g. 'Composite types require at least two >> members' or 'External types require both Input & Output conversion >> functions.' >> >> - additional_features.sql is poorly formatted (lack of proper indentation) >> >> Thanks! >> >> -- >> Dave Page >> Blog: http://pgsnake.blogspot.com >> Twitter: @pgsnake >> >> EnterpriseDB UK: http://www.enterprisedb.com >> The Enterprise PostgreSQL Company >> >> >> -- >> Sent via pgadmin-hackers mailing list (pgadmin-hackers@postgresql.org) >> To make changes to your subscription: >> http://www.postgresql.org/mailpref/pgadmin-hackers >> > > -- Dave Page Blog: http://pgsnake.blogspot.com Twitter: @pgsnake EnterpriseDB UK: http://www.enterprisedb.com The Enterprise PostgreSQL Company