Hi all,

I have noticed a strange behaviour regarding WAL sequence numbers. I am
populating a new DB with old data. To populate the largest part of the data
I use wal_level=minimal and archive_mode=off. Then I stop the database and
set wal_level=hotstandby and archive_mode=on. After I do that, I notice
that the WAL sequence number "rewinds" a little bit, overlaping with the
old ones... Is this normal?

Reply via email to