On Tue, 2024-01-09 at 17:48 +0530, Kiran K V wrote:
> I have a table with bytea column and trying to load the data using copy 
> command.
> But Copy command is failing with
> "ERROR: invalid byte sequence for encoding UTF8: 0x00.
> Why postgresql is failing to load when data contains 0x00.
> How to resolve this error ? any workaround to load the data with 0x00 values ?

This is not about loading data into a "bytea", but into a "text", "varchar" or
"char" column.  Check again.

Yours,
Laurenz Albe