On 2022-07-09 03:18, Peter Geoghegan wrote:
On Fri, Jul 8, 2022 at 10:47 AM Alvaro Herrera <alvhe...@alvh.no-ip.org> wrote:
Saving some sort of history would be much more useful, but of course a
lot more work.

Thank you for the comments!
Yes, having some sort of history would be ideal in this case.
However, I am not sure how to implement those features at this moment, so I will take some time to consider.

At the same time, I think having this metrics exposed in the pg_stat_all_tables comes in handy when tuning the maintenance_work_mem/autovacuume_work_mem even though it shows the value of only last vacuum/autovacuum.

Regards,

--
Ken Kato
Advanced Computing Technology Center
Research and Development Headquarters
NTT DATA CORPORATION


Reply via email to