On Wed, Sep 20, 2023 at 11:00 AM Hayato Kuroda (Fujitsu)
<kuroda.hay...@fujitsu.com> wrote:
>
> Dear Amit,
>
> Thank you for reviewing! PSA new version. In this version I ran pgindent 
> again.
>

+ /*
+ * There is a possibility that following records may be generated
+ * during the upgrade.
+ */
+ if (!CHECK_WAL_RECORD(rmid, info, RM_XLOG_ID, XLOG_CHECKPOINT_SHUTDOWN) &&
+ !CHECK_WAL_RECORD(rmid, info, RM_XLOG_ID, XLOG_CHECKPOINT_ONLINE) &&
+ !CHECK_WAL_RECORD(rmid, info, RM_XLOG_ID, XLOG_SWITCH) &&
+ !CHECK_WAL_RECORD(rmid, info, RM_XLOG_ID, XLOG_FPI_FOR_HINT) &&
+ !CHECK_WAL_RECORD(rmid, info, RM_XLOG_ID, XLOG_PARAMETER_CHANGE) &&
+ !CHECK_WAL_RECORD(rmid, info, RM_STANDBY_ID, XLOG_RUNNING_XACTS) &&
+ !CHECK_WAL_RECORD(rmid, info, RM_HEAP2_ID, XLOG_HEAP2_PRUNE))
+ is_valid = false;
+
+ CHECK_FOR_INTERRUPTS();

Just wondering why XLOG_HEAP2_VACUUM or other vacuum-related commands
can not occur during the upgrade?

-- 
Regards,
Dilip Kumar