On Mon, May 5, 2025 at 6:59 PM Amit Kapila wrote: > > On Sun, May 4, 2025 at 2:33 PM Masahiko Sawada > <[email protected]> wrote: > > > > While I cannot be entirely certain of my analysis, I believe the root > > cause might be related to the backward movement of the confirmed_flush > > LSN. The following scenario seems possible: > > > > 1. The walsender enables the two_phase and sets two_phase_at (which > > should be the same as confirmed_flush). > > 2. The slot's confirmed_flush regresses for some reason. > > 3. The slotsync worker retrieves the remote slot information and > > enables two_phase for the local slot. > > > > Yes, this is possible. Here is my theory as to how it can happen in the > current > case. In the failed test, after the primary has prepared a transaction, the > transaction won't be replicated to the subscriber as two_phase was not > enabled for the slot. However, subsequent keepalive messages can send the > latest WAL location to the subscriber and get the confirmation of the same > from > the subscriber without its origin being moved. Now, after we restart the apply > worker (due to disable/enable for a subscription), it will use the previous > origin_lsn to temporarily move back the confirmed flush LSN as explained in > one of the previous emails in another thread [1]. During this temporary > movement of confirm flush LSN, the slotsync worker fetches the two_phase_at > and confirm_flush_lsn values, leading to the assertion failure. We see this > issue intermittently because it depends on the timing of slotsync worker's > request to fetch the slot's value.
Based on this theory, I can reproduce the BF failure in the 040 tap-test on HEAD after applying the 0001 patch. This is achieved by using the injection point to stop the walsender from sending a keepalive before receiving the old origin position from the apply worker, ensuring the confirmed_flush consistently moves backward before slotsync. Additionally, I've reproduced the duplicate data issue on HEAD without slotsync using the attached script (after applying the injection point patch). This issue arises if we immediately disable the subscription after the confirm_flush_lsn moves backward, preventing the walsender from advancing the confirm_flush_lsn. In this case, if a prepared transaction exists before two_phase_at, then after re-enabling the subscription, it will replicate that prepared transaction when decoding the PREPARE record and replicate that again when decoding the COMMIT PREPARED record. In such cases, the apply worker keeps reporting the error: ERROR: transaction identifier "pg_gid_16387_755" is already in use. Apart from above, we're investigating whether the same issue can occur in back-branches and will share the results once ready. Best Regards, Hou zj
#!/bin/bash
port_primary=5432
port_secondary=5433
port_third=5434
port_secondary_2=5436
port_secondary_3=5437
port_subscriber=5434
port_subscriber2=5435
echo '=========='
echo '=Clean up='
echo '=========='
pg_ctl stop -D data_primary
pg_ctl stop -D data_secondary
pg_ctl stop -D data_third_
pg_ctl stop -D data_secondary_2
pg_ctl stop -D data_secondary_3
pg_ctl stop -D data_subscriber
pg_ctl stop -D data_subscriber2
rm -rf data_* *log
rm -rf /home/houzj/archivedir/*
echo '======================='
echo '=Set up primary server='
echo '======================='
initdb -D data_primary
cat << EOF >> data_primary/postgresql.conf
wal_level = logical
port = $port_primary
#standby_slot_names = 'physical'
#log_replication_commands = 'on'
#max_slot_wal_keep_size = 64kB
max_wal_senders=550
max_worker_processes=1000
max_replication_slots=550
log_replication_commands = 'on'
checkpoint_timeout = 1d
shared_buffers = 6GB
max_worker_processes = 32
max_parallel_maintenance_workers = 24
max_parallel_workers = 32
synchronous_commit = on
checkpoint_timeout = 1d
max_wal_size = 24GB
min_wal_size = 15GB
autovacuum = off
wal_sender_timeout = 6000s
wal_receiver_timeout = 6000s
#log_min_messages = 'debug2'
#archive_mode = on
#archive_command = 'cp %p /home/houzj/archivedir/%f'
#restore_command = 'cp /home/houzj/archivedir/%f %p'
max_prepared_transactions = 10
EOF
pg_ctl -D data_primary start -w -l primary.log
psql -d postgres -p $port_primary -c "SELECT * FROM
pg_create_physical_replication_slot('physical');"
echo '========================='
echo '=Set up secondary server='
echo '========================='
psql -d postgres -p $port_primary -c "CHECKPOINT;"
pg_basebackup -D data_secondary -p $port_primary
cat << EOF >> data_secondary/postgresql.conf
port = $port_secondary
primary_conninfo = 'port=$port_primary application_name=secondary
dbname=postgres'
#primary_conninfo = 'port=$port_primary application_name=secondary
dbname=postgreis'
primary_slot_name = 'physical'
hot_standby = on
hot_standby_feedback = on
#sync_replication_slots = on
#standby_slot_names = ''
EOF
cat << EOF >> data_secondary/standby.signal
EOF
pg_ctl -D data_secondary start -w
psql -d postgres -p $port_secondary -c "SELECT 'init' FROM
pg_create_logical_replication_slot('stuck', 'pgoutput');" &
sleep 1
psql -d postgres -p $port_primary -c "CHECKPOINT;"
echo '==================='
echo '=Set up subscirber='
echo '==================='
initdb -D data_subscriber
cat << EOF >> data_subscriber/postgresql.conf
port = $port_subscriber
checkpoint_timeout = 1h
shared_buffers = '8GB'
wal_buffers = '1GB'
max_connections = '5000'
max_wal_size = 20GB
min_wal_size = 10GB
max_wal_senders = 100
max_replication_slots = 101
autovacuum = off
wal_sender_timeout = 6000s
wal_receiver_timeout = 6000s
wal_receiver_status_interval = 1
max_prepared_transactions = 10
EOF
pg_ctl start -D data_subscriber
psql -d postgres -p $port_primary -c "CREATE TABLE tab1(a int); INSERT INTO
tab1 VALUES(1); CREATE PUBLICATION pub FOR TABLE tab1;"
psql -d postgres -p $port_subscriber -c "CREATE TABLE tab1(a int);"
psql -d postgres -p $port_subscriber -c "CREATE SUBSCRIPTION sub CONNECTION
'dbname=postgres port=$port_primary' PUBLICATION pub WITH
(slot_name='logicalslot', create_slot=true, copy_data = true, two_phase=false,
failover=true, enabled=true)"
sleep 2
psql -d postgres -p $port_primary -c "INSERT INTO tab1 VALUES(1);"
psql -d postgres -p $port_primary -c "BEGIN; SELECT
pg_logical_emit_message(true, 'test', 'test'); PREPARE TRANSACTION
'slotsync_twophase_prepared';"
sleep 1
psql -d postgres -p $port_subscriber -c "alter subscription sub disable;"
sleep 1
psql -d postgres -p $port_primary -c "create extension injection_points;SELECT
injection_points_attach('process-replies', 'wait');"
psql -d postgres -p $port_subscriber -c "alter subscription sub set (two_phase
=on); alter subscription sub enable ;"
sleep 1
psql -d postgres -p $port_subscriber -c "alter subscription sub disable;"
psql -d postgres -p $port_primary -c "SELECT
injection_points_wakeup('process-replies');SELECT
injection_points_detach('process-replies');"
sleep 1
psql -d postgres -p $port_primary -c "COMMIT PREPARED
'slotsync_twophase_prepared';"
psql -d postgres -p $port_subscriber -c "alter subscription sub enable;"
sleep 1
exit
0001-reproduce-BF-failure-in-040_standby_failover_slots_s.patch
Description: 0001-reproduce-BF-failure-in-040_standby_failover_slots_s.patch