On Thu, Sep 11, 2025, at 10:07 PM, Efrain J. Berdecia wrote:
> The error I would like to address with this feature is the following:
>
> FATAL: highest timeline xxx of the primary is behind timeline yyy
>

It seems your procedure to set up a standby is incorrect. See [1]. You are not
using the base backup from the primary server.

You didn't describe the whole procedure so it is hard to point out where the
problem is.


[1] 
https://www.postgresql.org/docs/current/warm-standby.html#STANDBY-SERVER-SETUP


-- 
Euler Taveira
EDB   https://www.enterprisedb.com/