On Monday, March 9, 2026 11:17 AM Kuroda, Hayato/黒田 隼人 
<[email protected]> wrote:
> Few comments.

Thanks for the comments.

> 
> 03.
> Can we describe needed privileges? IIUC, initial sync needs the UPDATE
> privilege, additionally periodic synch needs SELECT privilege.

I could not find existing doc for the privilege required for table sync or
sequence sync, so I think we can consider that as a separate patch.

> 
> 04.
> ```
> +               long            sleep_ms = SEQSYNC_MIN_SLEEP_MS;
> ```
> 
> This is used in the for loop, make it the loop-specific variable.

This value should survive across sync loop as it's dynamically
adjusted in the loop.

Other comments have been addressed in latest version.

Best Regards,
Hou zj

Reply via email to