On Tue, 27 Aug 2019 14:07:48 +0800 mich...@paquier.xyz wrote: > There is a section in float4.sql which deals with overflow and > underflow, so wouldn't it be better to move the tests there? You > could just trigger the failures with that: > =# insert into float4_tbl values ('-10e-70'::float8); > ERROR: 22003: value out of range: underflow > LOCATION: check_float4_val, float.h:145 > =# insert into float4_tbl values ('-10e70'::float8); > ERROR: 22003: value out of range: overflow > LOCATION: check_float4_val, float.h:140 > I would also test all four patterns: 10e70, 10e-70, -10e70, -10e-70. I think your way is much better, so I change the patch and it is 'regression_20190827.patch' now.
> For the numeric part, this improves the case of > ApplySortAbbrevFullComparator() where both values are not NULL. Could > things be done so as the other code paths are fully covered? One > INSERT is fine by the way to add the extra coverage. There are code lines related to NULL values in ApplySortAbbrevFullComparator(), but I think the code lines for comparing a NULL and a NOT NULL can be never reached, because it is handled in ApplySortComparator() which is called before ApplySortAbbrevFullComparator(). So I think it is no use to INSERT a NULL value. -- Movead
regression_20190827.patch