On Sun, Jun 06, 2021 at 09:13:48PM -0500, Justin Pryzby wrote:
> Putting this into fd.c seems to assume that we can clobber "ps", which is fine
> when called by StartupXLOG(), but it's a public interface, so I'm not sure if
> it's okay to assume that's the only caller.  Maybe it should check if
> MyAuxProcType == B_STARTUP.

I would be tempted to just add that into StartupXLOG() rather than
implying that callers of SyncDataDirectory() are fine to get their ps
output enforced all the time.
--
Michael