On Mon, Oct 8, 2012 at 3:44 PM, Claudio Freire <klaussfre...@gmail.com>wrote:

> On Mon, Oct 8, 2012 at 7:25 PM, Craig James <cja...@emolecules.com> wrote:
> >> > But why? What have I overlooked?
> >>
> >> Do you have readahead properly set up on the new one?
> >
> >
> >  # blockdev --getra /dev/sdb1
> > 256
>
>
> It's probably this. 256 is way too low to saturate your I/O system.
> Pump it up. I've found 8192 works nice for a system I have, 32000 I
> guess could work too.
>

But again ... the two systems are identical.  This can't explain it.

Thanks,
Craig

Reply via email to