Santhosh Srinivasan updated PIG-335:
------------------------------------
Attachment: PIG_335_1.patch
New patch which fixes the logical to physical translator to use the load
function interface only in the case of bytearrays to pig types during object
construction and serialization.
> Casting does not work in certain cases with multiple loads
> ----------------------------------------------------------
>
> Key: PIG-335
> URL: https://issues.apache.org/jira/browse/PIG-335
> Project: Pig
> Issue Type: Bug
> Components: impl
> Affects Versions: types_branch
> Reporter: Alan Gates
> Assignee: Santhosh Srinivasan
> Priority: Critical
> Fix For: types_branch
>
> Attachments: PIG_335.patch, PIG_335_1.patch
>
>
> Given a script like:
> A = load 'bla' as (x, y) using Loader1();
> B = load 'morebla' as (s, t) using Loader2();
> C = cogroup A by x, B by s;
> D = foreach C generate flatten(A), flatten(B);
> E = foreach D generate x, y, t + 1;
> In this case, in the last foreach, a cast will need to be added to t + 1 to
> allow t (a byte array) to be added to an integer. We use load functions to
> handle this late casting. The issue is that we do not currently have a way
> to know whether to use Loader1 or Loader2 to cast the data. We need to track
> the lineage of fields so that the cast operator can select the correct loader.
--
This message is automatically generated by JIRA.
-