On Saturday, August 20, 2011 13:47:21 Weng Xuetian wrote: > Hi Plasma World, > I'm trying to run this example:https://projects.kde.org/projects/kde/kdeexamples/repository/revisions/maste > r/entry/plasma/javascript/plasmoids/usingServices/ > In spite of connectSource missing a time interval,
the time interval is optional, and in this case it would even be incorrect to include a time interval. it is updated when the data in the DataEngine updates, which happens when the state of the media player changes. so there is no reason to have a time interval there. > but the service job seems also not works. yes, this got broken (i think in 4.7). i'm not sure if this breakage was in our code or some change in Qt, but it no longer works, indeed. i've just fixed it for 4.7.1 and 4.8. sorry for the inconvenience :/ we really need a comprehensive unit test set for the JS (and QML) bindings. -- Aaron J. Seigo humru othro a kohnu se GPG Fingerprint: 8B8B 2209 0C6F 7C47 B1EA EE75 D6B7 2EB1 A7F1 DB43 KDE core developer sponsored by Qt Development Frameworks
signature.asc
Description: This is a digitally signed message part.
_______________________________________________ Plasma-devel mailing list [email protected] https://mail.kde.org/mailman/listinfo/plasma-devel