On Saturday, August 20, 2011 13:47:21 Weng Xuetian wrote:
> Hi Plasma World,
> I'm trying to run this 
example:https://projects.kde.org/projects/kde/kdeexamples/repository/revisions/maste
> r/entry/plasma/javascript/plasmoids/usingServices/
> In spite of connectSource missing a time interval, 

the time interval is optional, and in this case it would even be incorrect to 
include a time interval. it is updated when the data in the DataEngine 
updates, which happens when the state of the media player changes. so there is 
no reason to have a time interval there.

> but the service job seems also not works.

yes, this got broken (i think in 4.7). i'm not sure if this breakage was in 
our code or some change in Qt, but it no longer works, indeed. i've just fixed 
it for 4.7.1 and 4.8. sorry for the inconvenience :/

we really need a comprehensive unit test set for the JS (and QML) bindings.

-- 
Aaron J. Seigo
humru othro a kohnu se
GPG Fingerprint: 8B8B 2209 0C6F 7C47 B1EA  EE75 D6B7 2EB1 A7F1 DB43

KDE core developer sponsored by Qt Development Frameworks

Attachment: signature.asc
Description: This is a digitally signed message part.

_______________________________________________
Plasma-devel mailing list
[email protected]
https://mail.kde.org/mailman/listinfo/plasma-devel

Reply via email to