wbauer created this revision. Restricted Application added a project: Plasma. Restricted Application added a subscriber: plasma-devel.
REVISION SUMMARY The structure was only freed in case the XTest method was chosen. But it should always be freed of course (as long as it isn't NULL). TEST PLAN Builds, old-style system tray icons are still displayed here. REPOSITORY R120 Plasma Workspace REVISION DETAIL https://phabricator.kde.org/D6389 AFFECTED FILES xembed-sni-proxy/sniproxy.cpp To: wbauer, davidedmundson Cc: plasma-devel, ZrenBot, progwolff, lesliezhai, ali-mohamed, jensreuterberg, abetts, sebas, apol, mart, lukas