Author: qboosh                       Date: Sun Jul  8 18:32:48 2007 GMT
Module: SPECS                         Tag: HEAD
---- Log message:
- pl, URL

---- Files affected:
SPECS:
   raidutils.spec (1.3 -> 1.4) 

---- Diffs:

================================================================
Index: SPECS/raidutils.spec
diff -u SPECS/raidutils.spec:1.3 SPECS/raidutils.spec:1.4
--- SPECS/raidutils.spec:1.3    Sat Jun 23 13:57:24 2007
+++ SPECS/raidutils.spec        Sun Jul  8 20:32:42 2007
@@ -1,6 +1,6 @@
 # $Revision$, $Date$
 Summary:       Utilities to manage Adaptec I2O compliant RAID controllers
-Summary(pl):   Narz�dzia do zarz�dzania kontrolerami RAID I2O Adaptec
+Summary(pl.UTF-8):     Narz�dzia do zarz�dzania kontrolerami RAID Adaptec I2O
 Name:          raidutils
 Version:       0.0.6
 Release:       1
@@ -9,6 +9,7 @@
 Source0:       
http://i2o.shadowconnect.com/raidutils/%{name}-%{version}.tar.bz2
 Patch0:                %{name}-suse.patch
 # Source0-md5: d32ed6789a11dca51cbc6d4428e26d8b
+URL:           http://i2o.shadowconnect.com/
 BuildRequires: autoconf
 BuildRoot:     %{tmpdir}/%{name}-%{version}-root-%(id -u -n)
 
@@ -19,6 +20,12 @@
 activate/silence the alarm or get information about the status of the
 RAID array and disks.
 
+%description -l pl.UTF-8
+Program raidutils pozwala zarz�dza� kontrolerami RAID zgodnymi z
+Adaptec I2O. Potrafi na przyk�ad utworzy�/usun�� macierz RAID,
+doda�/usun�� dysk hot spare do/z macierzy RAID, uaktywni�/wy��czy�
+alarm albo uzyska� informacje o stanie macierzy RAID i jej dysk�w.
+
 %prep
 %setup -q
 %patch0 -p1
@@ -30,26 +37,25 @@
 
 %install
 rm -rf $RPM_BUILD_ROOT
+
 %{__make} install \
        DESTDIR=$RPM_BUILD_ROOT
-rm $RPM_BUILD_ROOT%{_libdir}/libraidutil.a
-rm $RPM_BUILD_ROOT%{_libdir}/libraidutil.so
-rm $RPM_BUILD_ROOT%{_libdir}/libraidutil.la
+
+rm $RPM_BUILD_ROOT%{_libdir}/libraidutil.{a,la,so}
 
 %clean
 rm -rf $RPM_BUILD_ROOT
 
-%post -p /sbin/ldconfig
-%postun -p /sbin/ldconfig
+%post  -p /sbin/ldconfig
+%postun        -p /sbin/ldconfig
 
 %files
 %defattr(644,root,root,755)
-%doc README COPYING ChangeLog
-
+%doc COPYING ChangeLog README
 %attr(755,root,root) %{_bindir}/raidutil
 %attr(755,root,root) %{_bindir}/raideng
-%attr(755,root,root) %{_libdir}/libraidutil.so.0
-%attr(755,root,root) %{_libdir}/libraidutil.so.0.0.0
+%attr(755,root,root) %{_libdir}/libraidutil.so.*.*.*
+%attr(755,root,root) %ghost %{_libdir}/libraidutil.so.0
 
 %define date   %(echo `LC_ALL="C" date +"%a %b %d %Y"`)
 %changelog
@@ -57,6 +63,9 @@
 All persons listed below can be reached at <cvs_login>@pld-linux.org
 
 $Log$
+Revision 1.4  2007/07/08 18:32:42  qboosh
+- pl, URL
+
 Revision 1.3  2007/06/23 11:57:24  marcus
 - suse patch
 
================================================================

---- CVS-web:
    http://cvs.pld-linux.org/SPECS/raidutils.spec?r1=1.3&r2=1.4&f=u

_______________________________________________
pld-cvs-commit mailing list
pld-cvs-commit@lists.pld-linux.org
http://lists.pld-linux.org/mailman/listinfo/pld-cvs-commit

Reply via email to