Author: bszx                         Date: Fri Oct  3 16:50:17 2008 GMT
Module: SOURCES                       Tag: HEAD
---- Log message:
- sometimes failed devices are before active ones

---- Files affected:
SOURCES:
   lilo-raid.patch (NONE -> 1.1)  (NEW)

---- Diffs:

================================================================
Index: SOURCES/lilo-raid.patch
diff -u /dev/null SOURCES/lilo-raid.patch:1.1
--- /dev/null   Fri Oct  3 18:50:18 2008
+++ SOURCES/lilo-raid.patch     Fri Oct  3 18:50:12 2008
@@ -0,0 +1,10 @@
+--- lilo-22.8/raid.c.old       2006-08-13 21:37:07.000000000 +0200
++++ lilo-22.8/raid.c   2008-10-03 18:41:58.000000000 +0200
+@@ -223,7 +223,6 @@
+           if (!force_raid) die("Not all RAID-1 disks are active; use '-H' to 
install to active disks only");
+           else {
+               warn("Partial RAID-1 install on active disks only; booting is 
not failsafe\n");
+-              raid_limit = md_array_info.active_disks;
+           }
+       }
+       raid_index = 0;
================================================================