Author: glen                         Date: Sat Mar 24 12:51:54 2012 GMT
Module: packages                      Tag: HEAD
---- Log message:
- sync with vboxnetadp

---- Files affected:
packages/VirtualBox:
   VirtualBox-vboxdrv.init (1.9 -> 1.10) 

---- Diffs:

================================================================
Index: packages/VirtualBox/VirtualBox-vboxdrv.init
diff -u packages/VirtualBox/VirtualBox-vboxdrv.init:1.9 
packages/VirtualBox/VirtualBox-vboxdrv.init:1.10
--- packages/VirtualBox/VirtualBox-vboxdrv.init:1.9     Thu Mar 22 15:11:40 2012
+++ packages/VirtualBox/VirtualBox-vboxdrv.init Sat Mar 24 13:51:49 2012
@@ -28,11 +28,11 @@
        # set proper $VBOX_DEVICE for systems with static dev
        show "Setting $VBOX_DEVICE entry"; busy
        rm -f $VBOX_DEVICE
-       VBOX_MAJOR=$(awk '$2 == "vboxdrv" {print $1}' /proc/devices)
+       VBOX_MAJOR=$(awk -vdevice="${VBOX_DEVICE#/dev/}" '$2 == device {print 
$1}' /proc/devices)
        if [ -n "$VBOX_MAJOR" ]; then
                VBOX_MINOR=0
        else
-               VBOX_MINOR=$(awk '$2 == "vboxdrv" {print $1}' /proc/misc)
+               VBOX_MINOR=$(awk -vdevice="${VBOX_DEVICE#/dev/}" '$2 == device 
{print $1}' /proc/misc)
                if [ -n "$VBOX_MINOR" ]; then
                        VBOX_MAJOR=$(awk '$2 == "misc" {print $1}' 
/proc/devices)
                fi
@@ -55,18 +55,27 @@
 }
 
 start() {
-       if [ -f /var/lock/subsys/vboxdrv ]; then
+       if [ -f /var/lock/subsys/$VBOX_MODULE ]; then
                return
        fi
 
        setup || exit $?
-       touch /var/lock/subsys/vboxdrv
+       touch /var/lock/subsys/$VBOX_MODULE
 }
 
 stop() {
        # NOTE: rmmod will wait if device is in use, so automatic rmmod 
probably is not the best idea
        /sbin/rmmod $VBOX_MODULE
-       rm -f /var/lock/subsys/vboxdrv
+       rm -f /var/lock/subsys/$VBOX_MODULE
+}
+
+condrestart() {
+       if [ -f /var/lock/subsys/$VBOX_MODULE ]; then
+               stop
+               start
+       else
+               RETVAL=$1
+       fi
 }
 
 RETVAL=0
@@ -82,6 +91,12 @@
        stop
        start
        ;;
+  try-restart)
+       condrestart 0
+       ;;
+  force-reload)
+       condrestart 7
+       ;;
   setup)
        setup
        ;;
@@ -100,7 +115,7 @@
        fi
        ;;
   *)
-       msg_usage "$0 {start|stop|restart|setup|status}"
+       msg_usage "$0 
{start|stop|restart|try-restart|force-reload|setup|status}"
        exit 3
 esac
 
================================================================

---- CVS-web:
    
http://cvs.pld-linux.org/packages/VirtualBox/VirtualBox-vboxdrv.init?r1=1.9&r2=1.10

_______________________________________________
pld-cvs-commit mailing list
[email protected]
http://lists.pld-linux.org/mailman/listinfo/pld-cvs-commit

Reply via email to