Author: blues                        Date: Thu Sep  7 21:52:49 2006 GMT
Module: SOURCES                       Tag: HEAD
---- Log message:
- now working

---- Files affected:
SOURCES:
   doldaconnect.init (1.1 -> 1.2) 

---- Diffs:

================================================================
Index: SOURCES/doldaconnect.init
diff -u SOURCES/doldaconnect.init:1.1 SOURCES/doldaconnect.init:1.2
--- SOURCES/doldaconnect.init:1.1       Thu Sep  7 23:00:35 2006
+++ SOURCES/doldaconnect.init   Thu Sep  7 23:52:44 2006
@@ -18,13 +18,9 @@
 fi
 
 # Check that networking is up.
-if is_yes "${NETWORKING}"; then
-       if [ ! -f /var/lock/subsys/network -a "$1" != stop -a "$1" != status ]; 
then
-               msg_network_down doldacon
-               exit 1
-       fi
-else
-       exit 0
+if [ ! -f /var/lock/subsys/network -a "$1" != stop -a "$1" != status ]; then
+       msg_network_down doldacon
+       exit 1
 fi
 
 # See how we were called.
@@ -33,7 +29,7 @@
                # Check if service is already running?
                if [ ! -f /var/lock/subsys/doldacond ]; then
                        msg_starting doldacond
-                       daemon doldacond -p /var/run/doldacond.pid ${ADD_OPT}
+                       daemon doldacond -C /etc/doldaconnect/doldacond.conf -p 
/var/run/doldacond.pid ${ADD_OPT}
                        RETVAL=$?
                        [ $RETVAL -eq 0 ] && touch /var/lock/subsys/doldacond
                else
@@ -43,7 +39,7 @@
        stop)
                if [ -f /var/lock/subsys/doldacond ]; then
                        msg_stopping doldacond
-                       killproc doldacond --pidfile /var/run/doldacond.pid
+                       killproc --pidfile /var/run/doldacond.pid doldacond
                        rm -f /var/lock/subsys/doldacond
                else
                        msg_not_running doldacond
@@ -56,7 +52,7 @@
        reload)
                if [ -f /var/lock/subsys/doldacond ]; then
                        msg_reloading doldacond
-                       killproc doldacond -HUP
+                       killproc --pidfile /var/run/doldacond.pid doldacond -HUP
                        RETVAL=$?
                else
                        msg_not_running doldacond >&2
================================================================

---- CVS-web:
    http://cvs.pld-linux.org/SOURCES/doldaconnect.init?r1=1.1&r2=1.2&f=u

_______________________________________________
pld-cvs-commit mailing list
[email protected]
http://lists.pld-linux.org/mailman/listinfo/pld-cvs-commit

Reply via email to