ralphy wrote: 
> Thanks for looking into this Greg.
> 
> That local volume variable is not used anywhere in the function, nor is
> there any other reference to volume in the file.
> 
> It was added when Triode merged rpress' VU meter implemention for
> jivelite in Oct 2013.
> 
> I've commented out the line for now to confirm.

Hi ralphy,

Do you think it was at the same time that the VU Meters were made to
respond to the output signal strength rather than the input signal
strength?

What do other people think of the current VU Meters behaviour?

regards
Greg


------------------------------------------------------------------------
Greg Erskine's Profile: http://forums.slimdevices.com/member.php?userid=7403
View this thread: http://forums.slimdevices.com/showthread.php?t=104486