    Description: 
Section 13.6.3 of the Portlet 3.0 Spec indicates:
{quote}
The @PortletListener annotation designates a portlet URL generation listener 
class. The portlet URL generation listener class must implement the 
PortletURLGenerationListener interface.

If more than one class is annotated, the order of execution is determined by 
the ordinal
element within the @PortletListener annotation. Methods in annotated classes 
with a lower  ordinal number are executed before methods in classes with a 
higher ordinal number. If two annotated classes have the same ordinal number, 
the methods of both will be executed, but the
execution order will be undetermined.
{quote}

In addition {{<ordinal>}} sub-element has been added as an equivalent in 
portlet.xml -- For example:

{code:xml|title=WEB-INF/portlet.xml}
<listener>
        <ordinal>2</ordinal>
        <listener-class>com.mycompany.ListenerX</listener-class>
</listener>
<listener>
        <ordinal>0</ordinal>
        <listener-class>com.mycompany.ListenerY</listener-class>
</listener>
<listener>
        <ordinal>1</ordinal>
        <listener-class>com.mycompany.ListenerZ</listener-class>
</listener>
{code}

This issue serves as a task for fortifying the TCK with tests that verify the 
ordering requirements listed above.

Attached is an example portlet that has console logging messages showing the 
execution order of PortletURLGenerationListeners.


  was:
Section 13.6.3 of the Portlet 3.0 Spec indicates:
{quote}
The @PortletListener annotation designates a portlet URL generation listener 
class. The portlet URL generation listener class must implement the 
PortletURLGenerationListener interface.

If more than one class is annotated, the order of execution is determined by 
the ordinal
element within the @PortletListener annotation. Methods in annotated classes 
with a lower  ordinal number are executed before methods in classes with a 
higher ordinal number. If two annotated classes have the same ordinal number, 
the methods of both will be executed, but the
execution order will be undetermined.
{quote}

In addition {{<ordinal>>}} sub-element has been added as an equivalent in 
portlet.xml -- For example:

{code:xml|title=WEB-INF/portlet.xml}
<listener>
        <ordinal>2</ordinal>
        <listener-class>com.mycompany.ListenerX</listener-class>
</listener>
<listener>
        <ordinal>0</ordinal>
        <listener-class>com.mycompany.ListenerY</listener-class>
</listener>
<listener>
        <ordinal>1</ordinal>
        <listener-class>com.mycompany.ListenerZ</listener-class>
</listener>
{code}

This issue serves as a task for fortifying the TCK with tests that verify the 
ordering requirements listed above.

Attached is an example portlet that has console logging messages showing the 
execution order of PortletURLGenerationListeners.



> TCK: PortletURLGenerationListener <ordinal> feature not tested by the TCK
> -------------------------------------------------------------------------
>
>                 Key: PLUTO-732
>                 URL: https://issues.apache.org/jira/browse/PLUTO-732
>             Project: Pluto
>          Issue Type: Bug
>          Components: tck
>    Affects Versions: 3.0.0, 3.0.1
>            Reporter: Neil Griffin
>            Assignee: Scott Nicklous
>            Priority: Major
>         Attachments: com.liferay.url.listener.portlet.zip
>
>
> Section 13.6.3 of the Portlet 3.0 Spec indicates:
> {quote}
> The @PortletListener annotation designates a portlet URL generation listener 
> class. The portlet URL generation listener class must implement the 
> PortletURLGenerationListener interface.
> If more than one class is annotated, the order of execution is determined by 
> the ordinal
> element within the @PortletListener annotation. Methods in annotated classes 
> with a lower  ordinal number are executed before methods in classes with a 
> higher ordinal number. If two annotated classes have the same ordinal number, 
> the methods of both will be executed, but the
> execution order will be undetermined.
> {quote}
> In addition {{<ordinal>}} sub-element has been added as an equivalent in 
> portlet.xml -- For example:
> {code:xml|title=WEB-INF/portlet.xml}
> <listener>
>       <ordinal>2</ordinal>
>       <listener-class>com.mycompany.ListenerX</listener-class>
> </listener>
> <listener>
>       <ordinal>0</ordinal>
>       <listener-class>com.mycompany.ListenerY</listener-class>
> </listener>
> <listener>
>       <ordinal>1</ordinal>
>       <listener-class>com.mycompany.ListenerZ</listener-class>
> </listener>
> {code}
> This issue serves as a task for fortifying the TCK with tests that verify the 
> ordering requirements listed above.
> Attached is an example portlet that has console logging messages showing the 
> execution order of PortletURLGenerationListeners.



--
This message was sent by Atlassian JIRA
(v7.6.3#76005)

Reply via email to