Hi Brian,

You are correct: there is a mistake in the docs (just fixed,
will be committed to CVS soon). Configuration directive to use
is sampling_rate rather than sfprobe_sampling_rate.

Cheers,
Paolo

On Thu, Oct 24, 2013 at 06:00:15PM -0400, Brian Rak wrote:
> I can't seem to configure the sampling rate for sfprobe.  I'm using
> pmacct 1.5.0rc1, and I get the following error:
> 
> WARN ( ./sfacctd.example ): Unknown key: sfprobe_sampling_rate. Line
> 6 ignored.
> 
> My configuration:
> 
> daemonize: true
> interface: eth0
> plugins: sfprobe
> sfprobe_agentsubid: 1337
> sfprobe_receiver: xxxx:6343
> sfprobe_sampling_rate: 16384
> 
> 
> _______________________________________________
> pmacct-discussion mailing list
> http://www.pmacct.net/#mailinglists

_______________________________________________
pmacct-discussion mailing list
http://www.pmacct.net/#mailinglists

Reply via email to