> On Aug 23, 2018, at 1:44 PM, Niels Hofmans <[email protected]> wrote:
>
> Hello guys,
>
> Just to let you know, it works perfect with the following piece of golang
> code I wrote: https://gist.github.com/HazCod/35d705ebf87704b976ceab58ba20ca21
>
> So no need for full fledged syslog-ng in my container, only this binary that
> listens and prints to stdout.
If the container image persists across restarts (which I'd expect is the case
for an MTA that might have queued mail) then this code may fail to start if/when
/dev/log already exists. With unix-domain sockets a server typically needs to
unlink() the socket before creating and listening on a new one.
--