Palo Verde provides the following response:

Palo Verde uses a heated pressure washer to decon boron; however, this must be 
done using the work control process.

Seth.



From: [email protected] [mailto:[email protected]] On Behalf Of 
[email protected]
Sent: Wednesday, August 11, 2010 10:56 PM
To: [email protected]
Subject: Powernet: Use of Steam Cleaners for Boric Acid removal...

SONGS HPD would like to know if your plant allows the use of Steam Cleaners for 
removal of Boric Acid deposits on pipes, valves, and other surfaces that have 
started to or could lead to corrosive damage? San Onofre is considering the use 
of these type of machines to more effectively decontaminate and/or remove Boric 
Acid deposits from identified leaks. Information regarding Engineering 
approvals requested/received for the use of this process on plant components 
and structures would facilitate the use of steam cleaning machines at SONGS. 
Also request specific safety instructions considered for the use of the 
machines and any specific training that may have been considered/implemented 
for the use of the machines. A report on the effectiveness of these machines 
would also be appreciated.


Jeff Carey
U2/3 Health Physics Supervisor
San Onofre Nuclear Generating Station
949-368-7545
x87545/87722
Pony mail: J72 ----------------------------------- Powernet - a service of the 
Health Physics Society Power Reactor Section Powernet archives at 
http://www.mail-archive.com/[email protected]/ Reply to: [email protected] If 
Questions, contact Mike Russell, CHP at [email protected]

Email Firewall made the following annotations

---------------------------------------------------------------------
--- NOTICE ---

This message is for the designated recipient only and may contain confidential, 
privileged or proprietary information.  If you have received it in error, 
please notify the sender immediately and delete the original and any copy or 
printout.  Unintended recipients are prohibited from making any other use of 
this e-mail.  Although we have taken reasonable precautions to ensure no 
viruses are present in this e-mail, we accept no liability for any loss or 
damage arising from the use of this e-mail or attachments, or for any delay or 
errors or omissions in the contents which result from e-mail transmission.

---------------------------------------------------------------------

Reply via email to