Linda,
Entergy has been using these vests. Grand Gulf has limited experience, but uses EDE ex to determine dose to the individual. We multibadge the workers involved and use the approved method from our procedures. To date I have not heard of any challenge from our regulators, We just finished jour Dose Assessment inspection with no challenges there. Feel free to contact me with questions, but if I can't answer it, I'll pass you on to a couple of people that have extensive experience at a couple of our other plants. Fred W. Rosser R. P. Supervisor Grand Gulf Nuclear Station 601 437-6571 ________________________________ From: [email protected] [mailto:[email protected]] On Behalf Of Sewell, Linda Sent: Monday, August 23, 2010 2:03 PM To: [email protected] Subject: Powernet: Personnel Shielding Vests Hi All, Are you using personnel shielding vests? If so, what are you doing for dose determination? If you are using these, please provide a contact for further information. Thanks, Linda Linda Sewell, CHP Senior Health Physicist Diablo Canyon Power Plant MS 119/1/117 PO Box 56 Avila Beach, CA 93424 805.545.4315 (voice) 805.545.2618 (fax) mailto:[email protected] <mailto:[email protected]>