Davis-Besse uses the same criteria except for what type of instrument to use.
----- Original Message ----- From: Randy.Heredia Sent: 08/27/2010 02:00 PM MST To: [email protected] Subject: Powernet: Hot Spot Definition Question SONGS uses: >100 mrem/hour and 5 times DDE measured at 30cm with an RO-2/RO-2A (or equivalent) as the standard for a Hot Spot definition, what does your plant use? Randall W. Heredia Health Physics General Foreman SONGS 949.368.9701 ----------------------------------------- The information contained in this message is intended only for the personal and confidential use of the recipient(s) named above. If the reader of this message is not the intended recipient or an agent responsible for delivering it to the intended recipient, you are hereby notified that you have received this document in error and that any review, dissemination, distribution, or copying of this message is strictly prohibited. If you have received this communication in error, please notify us immediately, and delete the original message.