Fermi2 - same as Brown's Ferry practice

Benjy Bertossi
Fermi2 - RP Supervisor
734-586-4935
[email protected]


                                                                       
             "Creamer, Charles                                         
             E"                                                        
             <[email protected]                                          To
             v>                        <[email protected]>             
             Sent by:                                                   cc
             owner-power...@hp                                         
             s1.org                                                Subject
                                       RE: Powernet: DPW               
                                                                       
             10/21/2010 06:11                                          
             PM                                                        
                                                                       
                                                                       
             Please respond to                                         
             [email protected]                                         
                                                                       
                                                                       




Browns Ferry does not use separate RWPs or tasks.  We do use separate dose
limits in our access control software.


Chuck Creamer
Charles E. Creamer
Health Physicist
Tennessee Valley Authority
Browns Ferry Nuclear Plant
P.O. Box 2000 (Mail Stop NAB-1G-BFN)
Decatur, Al. 35609-2000
Phone: 256-729-2983
Fax:  256-729-3101
Pager: 1-800-323-4853, pin 30-053
mailto:[email protected]



From: [email protected] [mailto:[email protected]] On Behalf Of
Thompson, David A
Sent: Thursday, October 21, 2010 4:26 PM
To: ([email protected])
Subject: Powernet: DPW

Duke Power requests information on how plants are restricting dose for
Declared Pregnant Workers. At Duke, restrictions are placed in the access
control system, with monthly admin limits, and admin limits for the
gestation period. We also place them on a unique RWP and task. Are others
using separate RWPs for DPWs.

David A. Thompson, CHP
Manager Nuclear Fleet RP/Chemistry
[email protected]
704-382-6773