Cooper Nuclear Station for the last year period, non-outage, has had 9 PCEs. 7 of the 9 were Particle with 6 of the 7 in CCAs.
Steven Rezab From: [email protected] [mailto:[email protected]] On Behalf Of Osburn, Willard C III Sent: Thursday, October 28, 2010 5:05 PM To: '[email protected]' Subject: Powernet: Very Quick PCE Benchmark McGuire would like to know, for a recent or typical year: What percentage (or how many) of your total PCEs are particles (DRPs)? Of your total PCEs, what percentage (or how many) DRP PCEs occur in clean areas? Note: Rough approximations or actual numbers will suffice! Thanks. Willard Osburn McGuire Nuclear Station 704 875-4245