DC Cook's response below.
"Beckham, Bob" <[email protected]> Sent by: [email protected] 06/21/2011 12:39 PM Please respond to [email protected] To "[email protected]" <[email protected]> cc Subject Powernet: Dose Assessment Software Duke Energy would appreciate any information you would provide on the following questions: 1) What software dose your site/EOF use for off-site dose assessment to the public (e.g., RASCAL, RADDOSE, MIDAS, home grown, etc.)? MIDAS 2) Has your site/company changed to a different software within the previous 2 years? Yes 3) IF the answer to question 2 is yes, would you briefly state why the change was made? We just recently changed from Dose Assessment Program (DAP) which was home grown. We switched because there were a lot of human performance traps in DAP and it was a straight line gaussian model with limited capabilities. Thanks in advance for your time. Bob Beckham | Scientist | Fleet Scientific Services | Radiation Protection | Duke Energy Carolinas, LLC 526 S. Church St. | Mail Stop EC07F | Charlotte, NC 28202 | 704-382-6713 office | 704-453-6002 cell