For skin dose Fermi uses VARSKIN 3, and REMedy for internal dose. However we think internal dose is easy to calculate using NUREG/CR-4884 retention factors and Federal Guidance Report 11 dose factors. If there were multiple body counts, NUREG/CR-4884 and Reg Guide 8.9 provide a chi square method to address this. (Also we think that while the more conservative ingestion dose factors are normally used, for Co-60 and Co-58 the factors corresponding to f1=5E-2 are justified.)
Tom VanderMey, CHP Principal Radiological Engineer DTE Energy, Fermi 2 734-586-1539 [email protected] wrote: ----- To: [email protected] From: Benjy P Bertossi <[email protected]> Sent by: [email protected] Date: 03/15/2012 11:21AM Subject: Re: Powernet: RE: Software for Dose Assessment Fermi - RADDOSE Benjy Bertossi Fermi2 - RP Supervisor 734-586-4935 [email protected] "Johnson, Graham T" ---03/15/2012 09:58:50 AM---Duke Energy asked this question a few months ago. Based on that Powernet and some calls, we develop From: "Johnson, Graham T" <[email protected]> To: "[email protected]" <[email protected]> Date: 03/15/2012 09:58 AM Subject: Powernet: RE: Software for Dose Assessment Sent by: [email protected] Duke Energy asked this question a few months ago. Based on that Powernet and some calls, we developed the list below. Anyone who believes their info is not correct, please weigh in. Thanks, Graham Johnson Duke Raddose SCE Raddose Palo Verde Raddose SONGS Raddose STP STAMPEDE (in house software) Ft. Calhoun EAGLE (in house software) Columbia Rascal (moving to URI soon) Exelon URI Entergy URI Progress Rascal 3.0.5 (moving to URI soon) Dominion MIDAS Beaver Valley MIDAS DC Cook MIDAS Diablo MIDAS VC Summer MIDAS (switching to URI soon) From: [email protected] [mailto:[email protected]] On Behalf Of Holmes, Stephen J Sent: Thursday, March 15, 2012 9:09 AM To: '[email protected]' Subject: Powernet: Software for Dose Assessment I am benchmarking what software other plants are using for dose assessment (and other Health Physics applications). We are looking to upgrade and would appreciate any feedback and recommendations. At Ginna we are currently using: Internal Dose Assessment INDOS Internal Dosimetry Code, Version 1.0, 1987, © 1987 Skrable Enterprises Inc. This is a DOS-based program which our IT tells us does not interface well with Windows 7 and requires a dot matrix printer to print the output. Skin Dose Assessment Varskin MOD2 I know that there are newer versions of Varskin available, but our procedures currently are based on MOD2. Shielding/Dose to Curie Calculations MegaShield, WMG Inc Thanks, -Steve Stephen J Holmes, PE Sr. Plant Health Physicist Constellation Energy - RE Ginna Plant [email protected] 585-771-3577; 585-545-1661 (cell) >>> This e-mail and any attachments are confidential, may contain legal, professional or other privileged information, and are intended solely for the addressee. If you are not the intended recipient, do not use the information in this e-mail in any way, delete this e-mail and notify the sender. -IP2
<<inline: [email protected]>>