Braidwood documents the QC checks on a separate log from the worker's
fit test information. 

 

Amanda L. Stenson

Exelon Corp - Braidwood NPS

RP Technical Specialist

(815)417-2712

________________________________

From: [email protected] [mailto:[email protected]] On Behalf
Of BJ Thompson
Sent: Monday, April 02, 2012 10:27 AM
To: [email protected]
Cc: [email protected]
Subject: Powernet: RE: Respiratory Question

 

North Anna does document the daily Quality Control check performed on
the Portacount fit testing machine.  It is documented on the respirator
fit test log which has the QC checks and the worker's fit test
information.

 

 

Barbara J. Thompson

Supervisor of Exposure Control

Dominion - North  Anna Power Station

Email:  [email protected]

Phone:  540-894-2605

Beeper: #3469

FAX:  540-894-2408

 

 

From: [email protected] [mailto:[email protected]] On Behalf
Of GOWDY, GREGORY M
Sent: Monday, April 02, 2012 11:12 AM
To: [email protected]
Subject: Powernet: Respiratory Question

 

Respiratory Question   

(If you use PORTACOUNTS for your respiratory system quantification);  Do
you document the daily Quality Control (QC) checks for the PORTACOUNT? 

 

Please send responses to Joy Price @ Health Physics and Safety Services,
V. C. Summer Nuclear Station,

 

Thanks,

Joy Price

[email protected]

 

 

 

Greg 

Greg Gowdy, PhD, CHP

Sr. Staff Health Physicist

V. C. Summer Nuclear Station

Jenkinsville, SC  29065

(803)-345-4426  (work)

(803)-873-1561  (cell)

 

 

 


CONFIDENTIALITY NOTICE: This electronic message contains information
which may be legally confidential and/or privileged and does not in any
case represent a firm ENERGY COMMODITY bid or offer relating thereto
which binds the sender without an additional express written
confirmation to that effect. The information is intended solely for the
individual or entity named above and access by anyone else is
unauthorized. If you are not the intended recipient, any disclosure,
copying, distribution, or use of the contents of this information is
prohibited and may be unlawful. If you have received this electronic
transmission in error, please reply immediately to the sender that you
have received the message in error, and delete it. Thank you.




-----------------------------------------
**************************************************
This e-mail and any of its attachments may contain Exelon
Corporation proprietary information, which is privileged,
confidential, or subject to copyright belonging to the Exelon
Corporation family of Companies. 
This e-mail is intended solely for the use of the individual or
entity to which it is addressed.  If you are not the intended
recipient of this e-mail, you are hereby notified that any
dissemination, distribution, copying, or action taken in relation
to the contents of and attachments to this e-mail is strictly
prohibited and may be unlawful.  If you have received this e-mail
in error, please notify the sender immediately and permanently
delete the original and any copy of this e-mail and any printout.
Thank You.
**************************************************

<<image001.jpg>>

Reply via email to